Bante901 Benchtop pH/Conductivity Meter
• Multiparameter pH/conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensation modes.
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.
Model | Bante901 |
pH | |
Range | -2.000 to 20.000pH |
Resolution | 0.001, 0.01, 0.1pH, selectable |
Accuracy | ±0.002pH |
Calibration Points | 1 to 5 points |
pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
mV | |
Range | ±1999.9mV |
Resolution | 0.1, 1mV, selectable |
Accuracy | ±0.2mV |
Conductivity | |
Range | 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution | 0.001, 0.01, 0.1, 1 |
Accuracy | ±0.5% F.S. |
Calibration Points | 1 to 5 points |
Calibration Solutions | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
Temperature Coefficient | Linear (0.0 to 10.0%/°C), pure water |
Reference Temperature | 20/25°C |
Cell Constant | K=0.1, 1, 10 or custom |
TDS | |
Range | 0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | 0.01, 0.1, 1 |
Accuracy | ±1% F.S. |
TDS Factor | 0.1 to 1.0 (default 0.5) |
Temperature | |
Range | 0 to 105°C/32 to 221°F |
Resolution | 0.1°C/0.1°F |
Accuracy | ±0.5°C/±0.9°F |
Offset Calibration | 1 point |
Calibration Range | Reading ±10°C |
General Specifications | |
Temperature Compensation | 0 to 100°C/32 to 212°F, manual or automatic |
Stability Criteria | Low or high |
Calibration Due Alarm | 1 to 31 days or off |
Memory | Stores up to 500 data sets |
Output | USB communication interface |
Connector | BNC, 6-pin nimi-DIN, 3.5mm jack socket |
Display | Custom LCD (125×100mm) |
Power | DC5V, using AC adapter, 220V/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |